Jinsheng Material Technology Co., Ltd.
User: Jinsheng Material Technology Co., Ltd. Name: Low-voltage automatic reactive power compensation and harmonic control device Model: MSFGD-4680/1.0 Load: 2 sets of 40 tons of refining furnace, 2 with 1 1. Power factor: The power factor is increased from 0.88 to over 0.95, saving electricity costs by about 2%, and the smelting cycle is significantly shortened; 2. Filtering effect: 5, 7, and 11 harmonic currents are reduced to 2.7%, 1.6%, and 1.4%, respectively; 3. Temperature noise: The transformer uses temperature and noise is significantly reduced, and the transformer is loaded with load. Ability to extend the life of the transformer period; 4. Supporting components: The management device adopts the LCD screen for status display and human-computer interaction and targets Various possible faults are accompanied by comprehensive protection measures and fast discharge devices are installed.
2023-01-12
User: Huizhou People's Hospital Name: Low-voltage automatic reactive power compensation and harmonic control device Model: MSFGD-1440/0.4 Load: precision medical measuring instrument equipment 1. Power factor: The power factor is increased from 0.88 to over 0.95, saving about 2% of electricity costs; 2. Filtering effect: 5, 7, and 11 harmonic currents are reduced to 4.7%, 3.5%, and 2.2%, respectively; 3. Temperature noise: The temperature and noise of the transformer are significantly reduced, the load capacity of the transformer is enhanced, and the service life of the transformer is prolonged; 4. Supporting components: The management device adopts the LCD screen for status display and human-computer interaction, and completes the protection measures for various possible faults, and installs a rapid discharge device.
2023-01-12
Foshan Anke Anchor Chain Co., Ltd.
User: Foshan Anke Anchor Chain Co., Ltd. Name: Low-voltage automatic reactive power compensation and harmonic elimination device Model: TSCGD-1800/0.4 Load: induction heating furnace and electric welder 1. Power factor: the power factor is increased from about 0.5 to over 0.90; 2. Filtering effect: The 5th harmonic current drop is 1.6% of the fundamental current, and the 7th harmonic current drop is 1.3% of the fundamental current; 3. Temperature noise: The transformer uses temperature and noise is significantly reduced, so that the transformer capacity is obtained. Take advantage of; 4. Supporting components: LCD display for status display and human-computer interaction and for various possibilities The fault is accompanied by perfect protection measures.
2023-01-12
Hunan Changsha Lansi Technology Co., Ltd.
User: Hunan Changsha Lansi Technology Co., Ltd. Name: Low-voltage automatic reactive power compensation and harmonic elimination device Model: MSCGD-1800/0.4 Load: crystal growth furnace 1. Power factor: increase the power factor of the system, the monthly average power factor is not less than 0.90; 2. Filtering effect: 5th harmonic current drop is 1.4% of fundamental current, 5th harmonic current drop For 3.3% of the fundamental current, the 7th harmonic current drop is 2.3% of the fundamental current: 3. Temperature noise: The temperature and noise of the transformer are significantly reduced, so that the transformer capacity is fully utilized; 4. With components: LCD display for status display and human-computer interaction and for various possibilities The fault is accompanied by perfect protection measures.
2023-01-12
Gansu Jinchang Chemical Industry Group Co., Ltd.
User: Gansu Jinchang Chemical Industry Group Co., Ltd. Name: Equipment Level Filter Model: SSFGD-220/0.4 Load: air compressor, motor with frequency converter 1. Power factor: increase the power factor of the system from 0.86 to 1.00; 2. Filtering effect: The total harmonic current distortion rate decreased from 57.2% to 5.9%; 3. Temperature noise: sharp noise disappears, ΔT decreases by 5K, making the transformer capacity fully utilized; 4. Other equipment problems: After filtering, the instrument display is correct, the industrial control has no abnormality, and no error protection.
2023-01-12
Shenzhen Waterma Battery Co., Ltd.
用户:深圳市沃特玛电池有限公司名称:设备级滤波器型号:SSFGD-220/0.4负荷:380V交流充电桩1.滤波效果:总谐波电流畸变率由29%下降到4.6%;2.对充电桩影响:降低充电桩计量误差,