User: Shenzhen Shajing Changliupo Water Plant Name: High-voltage automatic reactive power compensation and harmonic control device Model: MSFGD-270/10 Load: several pumps with variable frequency energy saving 1. Power factor: The power factor is increased from 0.86 to 0.93, saving about 2% of electricity costs; 2. Filtering effect: no fault occurs after installation, the harmonic current is significantly reduced, and the 5th harmonic is reduced to 2.5% of the fundamental current; 3. Temperature noise: the pump runs smoothly, no abnormal noise; the temperature and noise of the treatment device are stable; 4. Supporting components: LCD display for status display and human-computer interaction, display is intuitive and easy to operate; and complete protection measures for various possible faults such as overvoltage and overcurrent.

User: Shenzhen Shajing Changliupo Water Plant
Name: High-voltage automatic reactive power compensation and harmonic control device
Model: MSFGD-270/10
Load: several pumps with variable frequency energy saving
 
1. Power factor: The power factor is increased from 0.86 to 0.93, saving about 2% of electricity costs;
2. Filtering effect: no fault occurs after installation, the harmonic current is significantly reduced, and the 5th harmonic is reduced to 2.5% of the fundamental current;
3. Temperature noise: the pump runs smoothly, no abnormal noise; the temperature and noise of the treatment device are stable;
4. Supporting components: LCD display for status display and human-computer interaction, display is intuitive and easy to operate; and complete protection measures for various possible faults such as overvoltage and overcurrent.