
The precision medical measurement equipment of the People's Hospital has the following features: 1. Power Factor: The power factor has been improved from 0.88 to above 0.95, saving about 2% on electricity costs; 2. Filtering Effect: The harmonic currents of the 5th, 7th, and 11th orders have been reduced to 4.7%, 3.5%, and 2.2%, respectively; 3. Temperature Noise: The operating temperature and noise of the transformer have significantly decreased, enhancing the load capacity of the transformer and extending its service life; 4. Supporting Components: The treatment device uses an LCD screen for status display and human-machine interaction.
2025-02-13
User: Foshan Anke Anchor Chain Co., Ltd. Name: Low Voltage Automatic Reactive Power Compensation and Harmonic Suppression Device Model: TSCGD-1800/0.4 Load: Induction heating furnace and electric welder 1. Power Factor: The power factor is improved from around 0.5 to over 0.90; 2. Filtering Effect: The 5th harmonic current is reduced to 1.6% of the fundamental current, and the 7th harmonic current is reduced to 1.3% of the fundamental current; 3. Temperature Noise: The operating temperature and noise of the transformer are significantly reduced, allowing for full utilization of the transformer capacity; 4. Supporting Components: An LCD screen is used for status display and human-machine interaction, and it is equipped with solutions for various possible faults.
2025-02-13
User: Hunan Changsha Lansi Technology Co., Ltd. Name: Low Voltage Automatic Reactive Power Compensation and Harmonic Elimination Device Model: MSCGD-1800/0.4 Load: Changjing Furnace 1. 1. Power Factor: Improve the system's power factor, with a monthly average power factor not lower than 0.90; 2. Filtering Effect: 5th harmonic current reduced to 1.4% of the fundamental current, 5th harmonic current reduced to 3.3% of the fundamental current, 7th harmonic current reduced to 2.3% of the fundamental current; 3. Temperature Noise: Transformer operating temperature and noise significantly reduced, allowing full utilization of transformer capacity; 4. Auxiliary Components: Uses a liquid crystal display for status indication.
2025-02-13
After the operation of the dynamic capacitor compensation cabinet - low-voltage automatic reactive power compensation and harmonic suppression device MSCGD, the system power factor improved from around 0.44 to about 0.92, and the system current decreased from approximately 1250A to 840A. This solution addresses the user's power quality issues, saves over 10% on electricity costs, improves the power factor, suppresses harmonics, and reduces system current, enhancing the quality of electricity usage.
2025-02-13
After the operation of the low-voltage reactive power compensation and harmonic suppression device from Lidar Electric, the system power factor of the crystal furnace at Lens Technology (Hunan) Co., Ltd. improved from around 0.80 to over 0.95. The system current decreased from approximately 2500A to 1865A, the absolute value of the 3rd harmonic current distortion reduced from 300A to 56A, and the absolute value of the 5th harmonic current distortion decreased from 125A to 93A. This solution addressed the user's power quality issues and saved over 10% in electricity costs.
2025-02-13
After the operation of the dynamic capacitor compensation cabinet - low-voltage dynamic reactive power compensation and filtering device TSFGD, the system power factor improved from around 0.83 to over 0.95. The average operating current of the system decreased from 820A to 580A, solving the user's power quality issues and saving more than 10% on electricity costs. It enhances the power factor, suppresses harmonics, and reduces system current, improving the quality of electricity usage.
2025-02-13
Follow Us

Guangdong Guangda Electric Co. Ltd.
Tel:18028173868
E-mail:gdgddq@126.com
Web:www.gd96.com
Add :Building 3, No. 613, Xingtan Shuixiang Avenue, Gaozan Village, Xingtan Town, Shunde District, Foshan City, Guangdong Province