Series Reactor

CKGD series reactors are connected in series in the compensation capacitor circuit,can inhibit the closing inrush current,It plays an important role in suppressing harmonics and preventing resonance events from occurring.The iron core is cold rolled with high quality and low loss,the coil is enameled wire with high temperature resistance.Low loss,high harmonic resistance,Electrical performance for low noise operation.

Hotline:

Product Consultation
  • Summary
  • Product Selection
  • Distinction
  • Parameter
  • Explain
  • Size
    • Commodity name: Series Reactor

    CKGD series reactors are connected in series in the compensation capacitor circuit,can inhibit the closing inrush current,It plays an important role in suppressing harmonics and preventing resonance events from occurring.The iron core is cold rolled with high quality and low loss,the coil is enameled wire with high temperature resistance.Low loss,high harmonic resistance,Electrical performance for low noise operation.

    CKGD series reactors are connected in series in the compensation capacitor circuit,can inhibit the closing inrush current,It plays an important role in suppressing harmonics and preventing resonance events from occurring.The iron core is cold rolled with high quality and low loss,the coil is enameled wire with high temperature resistance.Low loss,high harmonic resistance,Electrical performance for low noise operation.

    Key words:
    • series
    • high
    • in
    • the
    • loss
    • is
    • low
    • and
    • with
  • img

  • ►H class high temperature insulating material.

    ►Simple structure, beautiful appearance, less insulation material safety.

    ►With air duct, uniform temperature inside and outside, long service life.

    ►Low loss, low temperature rise, low noise, low operating cost.

    ►It is 1.3~2 times heavier than the products of the same type in the market.

  • Location

    Indoor only,altitude ≤1000mm (altitude above this value can be customized)

    Capacity error

    0~+10%


    Insulation

    0.23kV~0.69kV,AC3500V/60s


    Frequency

    50Hz/60Hz


    Reactance rate

    7%、12%、14%


    Temperture

    -20°C~+55°C


    Temperature rise

    Rated current operating coil temperature rise shall not exceed 55℃ (resistance method)


    Noise

    Rated current operating noise ≤60dB


    Low loss

    ≤0.023kW/kvar(Reference temperature 20℃)

  • Un=400V,Cn=480V,f=50Hz  k=7%

    Reactors Model

    Installation dimensions(mm)

    Mounting hole(mm)

    QC

    Paired capacitor model

    Number of parallels

    W

    D

    H

    E

    F

    CKGD480-0.7/7P

    240

    140

    185

    200

    75

    10kvar

    MPGD480-10-3

    1

    CKGD480-1.05/7P

    240

    140

    195

    200

    75

    15kvar

    MPGD480-15-3

    1

    CKGD480-1.4/7P

    240

    140

    215

    200

    75

    20kvar

    MPGD480-20-3

    1

    CKGD480-1.75/7P

    240

    140

    240

    200

    75

    25kvar

    MPGD480-25-3

    1

    CKGD480-2.1/7P

    240

    140

    260

    200

    75

    30kvar

    MPGD480-30-3

    1

    CKGD480-2.8/7P

    240

    140

    280

    200

    75

    40kvar

    MPGD480-40-3

    1

    CKGD480-3.5/7P

    240

    150

    280

    200

    80

    50kvar

    MPGD480-25-3

    2

    CKGD480-4.2/7P

    240

    165

    280

    200

    85

    60kvar

    MPGD480-30-3

    2

     

    Un=400V,Cn=525V,f=50Hz k=14%

    Reactors Model

    Installation dimensions(mm)

    Mounting hole(mm)

    QC

    Paired capacitor model

    Number of parallels

    W

    D

    H

    E

    F

    CKGD525-1.4/14P

    240

    135

    195

    200

    72

    10kvar

    MPGD525-10-3

    1

    CKGD525-2.1/14P

    240

    135

    240

    200

    72

    15kvar

    MPGD525-15-3

    1

    CKGD525-2.8/14P

    240

    145

    240

    200

    85

    20kvar

    MPGD525-20-3

    1

    CKGD525-3.5/14P

    240

    160

    235

    200

    95

    25kvar

    MPGD525-25-3

    1

    CKGD525-4.2/14P

    240

    165

    255

    200

    95

    30kvar

    MPGD525-30-3

    1

    CKGD525-5.6/14P

    240

    180

    270

    200

    115

    40kvar

    MPGD525-40-3

    1

    CKGD525-7.0/14P

    240

    200

    290

    200

    125

    50kvar

    MPGD525-25-3

    2

    CKGD525-8.4/14P

    240

    210

    310

    200

    135

    60kvar

    MPGD525-30-3

    2

  • img

RELATED PRODUCTS

Temperature on-line monitoring device


WTGD-801 is a set of advanced and practical switch cabinet electric contact online temperature monitoring device, through the wireless temperature measurement module to the online temperature control points for real-time monitoring, and the wireless receiving module will be transmitted to the device through RS485 bus related data, through the LCD screen display the real-time temperature of each monitoring point, It has overtemperature alarm function, system platform function and data communication function.

Insulation on-line monitoring device


JYGD-01 insulation online monitoring device can on-line monitoring the insulation states of high and low voltage equipment, the use of the device for diagnostic line cables, insulators, surge arrester, vacuum switch devices such as the shortcomings and hidden danger of accidents in the early, control of sudden accidents, insulation monitoring of electrical equipment insulation performance of the stand or fall provides effective information, and directly influences the safe and reliable operation of the equipment.

Intelligent electricity monitoring terminal


GD-320 intelligent electricity monitoring terminal has the functions of high-precision three-phase voltage, current and power measurement, time-sharing billing, demand calculation, harmonic calculation, fixed-value off-limit, data freezing, residual current protection and temperature protection.

Device level filter


Device level filter is designed for power electronic equipment to reduce harmonic matching products, it can make the three-phase rectifier circuit generated harmonic current to meet any harmonic standard requirements, improve the anti-surge interference ability of equipment. It is the ideal supporting equipment for inverter, UPS, all kinds of power supply, intermediate frequency furnace and other power electronic equipment. Its products have long service life, small loss, currently belongs to the domestic industry leader.

Incoming / Outgoing reactor


Inverter special incoming line reactor, connected in series between inverter incoming line end and power supply, inhibit surge voltage and surge current, protect inverter; Improve the power factor of frequency converter and suppress harmonic current; Filter harmonic voltage and harmonic current to improve the quality of power grid. Series inverter dedicated line (output) reactor, in between the client and load frequency converter, reduce the power frequency transient overvoltage, improvement of the voltage distribution on long transmission line, ease to the inverter output three-phase imbalance, reduce energy loss on the line, to prevent possible since the excitation generator with long line resonance phenomenon.

Sinusoidal filter


Sinusoidal filter is mainly used to solve the harmonic problem at the output of the inverter. The sinusoidal filter can convert the PWM wave output of the inverter into sinusoidal wave, reduce the voltage impact of the PWM pulse output of the inverter, reduce the traveling wave reflection phenomenon at the motor end, and prevent the insulation breakdown of the motor, resulting in cable burst. The function of long-distance transmission of frequency converter is realized.