Wall-Mounted Active Power Filter Compensation Module
The active filtering compensation module is a modular product specially developed by Guangda Electric for dynamic harmonic mitigation in 0.4 kV power supply systems. Connected in parallel with the grid, it uses an external current transformer to continuously monitor the load current. Leveraging DSP, FPGA, and CPLD chips, along with cutting-edge rapid harmonic mitigation and reactive power extraction technologies, it swiftly analyzes the harmonic and reactive components of the load current. Based on user-defined setpoints, it generates PWM pulses to drive a bidirectional converter composed of three-level IGBT modules, thereby producing compensation currents that meet grid requirements. This enables dynamic, precise compensation of harmonic and reactive currents, ultimately enhancing power quality. Active modular power quality products comprise three types of modules: Static Var Generators (SVG), Three-Phase Unbalance Controllers (ASVG), and Active Power Filters (APF).
Category:
- Summary
- Product Selection
- Distinction
- Parameter
- Explain
- Size
-
- Commodity name: Wall-Mounted Active Power Filter Compensation Module
The active filtering compensation module is a modular product specially developed by Guangda Electric for dynamic harmonic mitigation in 0.4 kV power supply systems. Connected in parallel with the grid, it uses an external current transformer to continuously monitor the load current. Leveraging DSP, FPGA, and CPLD chips, along with cutting-edge rapid harmonic mitigation and reactive power extraction technologies, it swiftly analyzes the harmonic and reactive components of the load current. Based on user-defined setpoints, it generates PWM pulses to drive a bidirectional converter composed of three-level IGBT modules, thereby producing compensation currents that meet grid requirements. This enables dynamic, precise compensation of harmonic and reactive currents, ultimately enhancing power quality. Active modular power quality products comprise three types of modules: Static Var Generators (SVG), Three-Phase Unbalance Controllers (ASVG), and Active Power Filters (APF).
The active filter compensation module is a modular product developed by Guangda Electric specifically for dynamic harmonic mitigation in 0.4 kV power supply systems. Connected in parallel with the grid, it uses an external current transformer to continuously monitor the load current. Leveraging DSP, FPGA, and CPLD chips, combined with state-of-the-art fast harmonic mitigation and reactive power extraction technologies, it rapidly analyzes the harmonic and reactive components of the load current. Based on user‑defined setpoints, it generates PWM pulses that drive a bidirectional converter composed of three‑level IGBT modules, producing compensation currents that meet grid requirements. This enables dynamic, precise compensation of harmonic and reactive currents, thereby enhancing power quality.
Product Features:
► The module control single-board enclosure achieves an IP6X dust‑proof rating, with effective isolation between the control and power sections.
► Using the SOGI algorithm, the device’s total response time is less than 2 ms.
► Vertical modular design, saving space and reducing the number of cabinets; single-cabinet capacity: 600 kvar.
► Industry-leading IGBT redundancy design ensures that a single‑channel failure does not affect normal system operation.
► The output employs an interleaved parallel control scheme, which can reduce ripple current by nearly 40%.
► Intelligent sleep mode and a parallel‑operation system employ a round‑robin scheduling mechanism, evenly distributing workload under low‑load conditions to extend module lifespan.
► The operating status of each module can be monitored remotely.
► The APF can instantaneously compensate harmonics from the 2nd to the 51st order, offering a broader compensation range.
► The ASVG can compensate harmonics from the 2nd to the 23rd order, and both the harmonic compensation capacity and the reactive power compensation capacity can be set over the full range.
► SVG can provide full-range, instantaneous compensation for both inductive and capacitive reactive power, while simultaneously addressing three-phase imbalance.
Technical Specifications:
System Parameters
Grid voltage
400V (-40% to +20%)
Grid frequency
50 Hz/60 Hz (±10%)
Number of units that can be paralleled
Unlimited
Overall machine efficiency
≥98%
Wiring method
Three-phase three-wire / Three-phase four-wire
Heat loss
<2%
CT Instrument transformer
150/5~10000/5
Inbound method
Downstream line/Upstream line
Airflow method
Front and back / Top and bottom
Performance Metrics
Response time
<2ms
Number of filtering iterations
APFGD: 2–51 times; ASVGGD: 2–23
Cooling mode
Smart Air Cooling
Noise Indicator
<58dB
Fixed method
Drawer-style, wall-mounted, freestanding
Environmental parameters
Altitude
≤2000m, 2000m–4000m derating
Operating temperature
-10℃ to +50℃ (derated operation above 40℃)
Relative humidity
5%~95%, non-condensing

Specification and Model Description:
Rack-Mount (Drawer-Type) Module Selection Table
Products and Models
Installation dimensions (mm)
Mounting hole (mm)
Rated capacity
W
D
H
A
B
APFGD-50A/0.4-4M
540
660
150
525
100
50A
APFGD-100A/0.4-4M
100A
APFGD-150A/0.4-4M
170
150A
SVGGD-35kvar/0.4-4M
150
35kvar
SVGGD-70kvar/0.4-4M
70kvar
SVGGD-100kvar/0.4-4M
170
100kvar
Vertical Module Selection Table
Products and Models
Installation dimensions (mm)
Mounting hole (mm)
Rated capacity
W
D
H
A
B
APFGD-50A/0.4-4L
165
685
570
145
550
50A
APFGD-100A/0.4-4L
100A
APFGD-150A/0.4-4L
185
685
570
165
550
150A
SVGGD-35kvar/0.4-4L
165
685
570
145
550
35kvar
SVGGD-70kvar/0.4-4L
70kvar
SVGGD-100kvar/0.4-4L
185
685
570
165
550
100kvar
Wall-Mounted Module Selection Chart
Products and Models
Installation dimensions (mm)
Mounting hole (mm)
Rated capacity
W
D
H
A
B
APFGD-50A/0.4-4W
500
178
660
460
635
50A
APFGD-100A/0.4-4W
100A
APFGD-150A/0.4-4W
198
150A
SVGGD-35kvar/0.4-4W
178
35kvar
SVGGD-70kvar/0.4-4W
70kvar
SVGGD-100kvar/0.4-4W
198
100kvar
Product Selection:

Product Dimensions Diagram:
Design Requirements
- 1. All active modules are equipped with ventilation systems; the cabinet’s front panel must feature a perforated, ventilated design, and the rear panel must be fitted with a fan.
- 2. For a single cabinet with a capacity ≤ 300 kvar (A), the rear door must be equipped with four fans, each providing an exhaust airflow of no less than 40 m³/min.
- 3. For single cabinets with a capacity greater than 300 kvar (A), six fans must be installed on the rear door, with an exhaust airflow rate of no less than 60 m³/min.
- 4. When natural air cooling at the installation location of the active module cabinet is insufficient, an air-conditioning system must be installed in the room.
- 5. The equipment should undergo a power-off maintenance every three months, during which the cabinet door is opened and dust is cleaned out.
Key words:- Active filter
- active filtering
RELATED PRODUCTS
PRODUCT MESSAGE
Follow Us
Guangdong Guangda Electric Co. Ltd.
Tel:18028173868
E-mail:gdgddq@126.com
Web:www.gd96.com
Add :Building 3, No. 613, Xingtan Shuixiang Avenue, Gaozan Village, Xingtan Town, Shunde District, Foshan City, Guangdong Province