Intelligent filtering compensation module
ZBMGD intelligent filter compensation module is the third generation module product specially designed by Goodpower to reduce line loss and improve power factor and power quality for 0.4kV dynamic reactive power compensation system.It is mainly composed of knife melt switch, thyristor module, intelligent measurement and control protection unit, capacitor and reactor.With temperature and current display, with over temperature, over current, SCR breakdown, harmonic protection, remote monitoring of each module running state.Self-developed fast switching technology, suitable for impact load, need fast reactive power compensation electric load site.
Category:
- Summary
- Product Selection
- Distinction
- Parameter
- Explain
- Size
-
- Commodity name: Intelligent filtering compensation module
ZBMGD intelligent filter compensation module is the third generation module product specially designed by Goodpower to reduce line loss and improve power factor and power quality for 0.4kV dynamic reactive power compensation system.It is mainly composed of knife melt switch, thyristor module, intelligent measurement and control protection unit, capacitor and reactor.With temperature and current display, with over temperature, over current, SCR breakdown, harmonic protection, remote monitoring of each module running state.Self-developed fast switching technology, suitable for impact load, need fast reactive power compensation electric load site.
ZBMGD-T intelligent filter compensation module is the third generation module product specially designed by Goodpower to reduce line loss and improve power factor and power quality for 0.4kV dynamic reactive power compensation system.It is mainly composed of knife melt switch, thyristor module, intelligent measurement and control protection unit, capacitor and reactor.With temperature and current display, with over temperature, over current, SCR breakdown, harmonic protection, remote monitoring of each module running state.Self-developed fast switching technology, suitable for impact load, need fast reactive power compensation electric load site.
Key words:- module
- and
- power
- compensation
- is
- reactive
- for
- protection
- current
-
►33C certification, appearance invention patent, utility model patent products.
►Save space and quantity of cabinet, single cabinet capacity 640kvar.
►Independent temperature and current display, over temperature, over current, SCR breakdown, harmonic protection.
►Switching response time ≤10ms, suitable for co-complement, sub-complement and phase compensation.
►Remotely monitor the current and temperature of each module.
►Metal case, non-flammable.
►Low temperature rise (20K), loss less than 1%.
-
Location
Indoor only,altitude ≤2000mm (altitude above this value can be customized)
System voltage
0.4kV
The voltage allows deviation
±10%
Frequency
50Hz
Relative humidity
≤90%(40℃)
Ambient temperature
-20℃~50℃
Control the voltage
12V DC
Pitch interval
≤10ms(Thyristor)
-
Model
Installation dimensions(mm)
Mounting hole (mm)
Rated capacity
QcRated current
InWeight
Loss(kW)
W
D
H
A
B
ZBMGD-33.3/0.4-7T
140
490
450
100
380
33.3kvar
40A
39kg
0.295
ZBMGD-40/0.4-7T
140
490
480
100
380
40kvar
48A
41kg
0.349
ZBMGD-66.7/0.4-7T
200
650
450
140
550
66.7kvar
80A
67kg
0.521
ZBMGD-80/0.4-7T
200
650
480
140
550
80kvar
96A
74kg
0.637
-
Product size
Design drawings
Module assembly cabinet requirements
Design requirements
►ZBMGD modules are equipped with a ventilation system. The front door plate of the cabinet body should be perforated for ventilation, and the rear door should use a fan.
►Single cabinet capacity ≤400kvar, the rear door should use 4 fans, exhaust air volume is not less than 40m³/min.
►Single cabinet capacity>400kvar, the rear door should use 6 fans, exhaust air volume is not less than 60m³/min.
►If the temperature is too high, the service life of ZBMGD module will be reduced (the electrical life will be reduced by twice every 10℃ increase).
►When the natural air cooling at the installation site of the complete cabinet of ZBMGD module is insufficient, an air conditioning system needs to be installed in the room.
►When the device runs every 3 months, power should be cut off for maintenance. Open the cabinet door and clean the dust.