Low voltage dynamic reactive power compensation device
TSVGGD device is a new type of power electronic device to solve the power quality problem, the device adopts intelligent algorithm control, the reactive power, three-phase load unbalance, harmonic has comprehensive compensation ability, has superior performance in compensating reactive power, three-phase unbalance, harmonic and so on, to achieve rapid continuous regulation of reactive power.
Product Consultation- Summary
- Product Selection
- Distinction
- Parameter
- Explain
- Size
-
- Commodity name: Low voltage dynamic reactive power compensation device
TSVGGD device is a new type of power electronic device to solve the power quality problem, the device adopts intelligent algorithm control, the reactive power, three-phase load unbalance, harmonic has comprehensive compensation ability, has superior performance in compensating reactive power, three-phase unbalance, harmonic and so on, to achieve rapid continuous regulation of reactive power.
TSVGGD device is a new type of power electronic device to solve the power quality problem, the device adopts intelligent algorithm control, the reactive power, three-phase load unbalance, harmonic has comprehensive compensation ability, has superior performance in compensating reactive power, three-phase unbalance, harmonic and so on, to achieve rapid continuous regulation of reactive power.
Key words:- reactive
- power
- the
- device
- three-phase
- of
- has
- harmonic
- unbalance
-
►Continuous adjustment of reactive power capacity to achieve stepless compensation.
►Reactive power can be dynamically adjusted bidirectional to compensate both inductive load and capacitive load.
►Each branch adopts modular products, independent protection system, energy management system remote monitoring module operating parameters.
►Each branch adopts modular products, independent protection system, energy management system remote monitoring module operating parameters.
►With four quadrant reactive power algorithm, suitable for photovoltaic system compensation
►Device specific CQC certification report.
-
Location
Indoor only,altitude ≤2000mm
Electrical connection
Three phase four wire/three phase three wire
System voltage
0.4kV
Voltage deviation
±15%
Frequency
50Hz
Relative humidity
≤90%(40℃)
Ambient temperature
-20℃~+50℃
Control the voltage
12V DC
Pitch interval
≤10ms(Thyristor)
Communication mode
RS485
Number of parallel stations
Parallel expansion, depending on the size of the cabinet, the maximum number of a cabinet is 8
Filtering range
Filter out 2~51 characteristic harmonic
-
Transformer capacity(kVA)
Installed capacity(kvar)
Output capacity(kvar)
Configuration of intelligent filter compensation module
Reactance rate
Circuit breaker in cabinet
Cabinet size
(W*D*H)630
267+100A
200+100A
2x33.3+3x66.7+100A
7%
630A
800x800x2200
800
334+150
250+150A
2x33.3+4x66.7+150A
7%
800A
1000x800x2200
1000
400+150A
300+150A
2x33.3+5x66.7+150A
7%
800A
1000x800x2200
1250
440+200A
330+200A
1x40+5x80+2*100A
7%
1000A
1000x800x2200
1600
634+250A
475+250A
1x33.3+9x66.7+150A+100A
7%
800A
2x(1000x800x2200)
2000
800+300A
600+300A
2x33.3+11x66.7+2x150A
7%
1000A
2x(1000x800x2200)
2500
1000+400A
750+400A
2x33.3+14x66.7+4x100A
7%
800A
3x(1000x800x2200)
3150
1280+600A
960+600A
16x80+4x150A
7%
1000A
3x(1000x800x2200)
-
Module assembly cabinet requirements
Design requirements
- 1.ZBMGD modules are equipped with a ventilation system. The front door plate of the cabinet body should be perforated for ventilation, and the rear door should use a fan.
- 2.Single cabinet capacity ≤400kvar, the rear door should use 4 fans, exhaust air volume is not less than 40m³/min.
- 3.Single cabinet capacity>400kvar, the rear door should use 6 fans, exhaust air volume is not less than 60m³/min.
- 4.If the temperature is too high, the service life of ZBMGD module will be reduced (the electrical life will be reduced by twice every 10℃ increase).
- 5.When the natural air cooling at the installation site of the complete cabinet of ZBMGD module is insufficient, an air conditioning system needs to be installed in the room.