TSVGGD Dynamic Compensation Filter Cabinet
The TSVGGD device is a novel power electronic system designed to address power quality issues. It employs intelligent control algorithms and offers comprehensive compensation for reactive power, three-phase load imbalance, and harmonics. With superior performance in compensating reactive power, three-phase imbalance, and harmonics, it enables rapid, continuous regulation of reactive power.
Product Consultation- Summary
- Product Selection
- Distinction
- Parameter
- Explain
- Size
-
- Commodity name: TSVGGD Dynamic Compensation Filter Cabinet
The TSVGGD device is a novel power electronic system designed to address power quality issues. It employs intelligent control algorithms and offers comprehensive compensation for reactive power, three-phase load imbalance, and harmonics. With superior performance in compensating reactive power, three-phase imbalance, and harmonics, it enables rapid, continuous regulation of reactive power.
The TSVGGD device is a novel power electronic solution for addressing power quality issues. It employs intelligent control algorithms and offers comprehensive compensation for reactive power, three-phase load imbalance, and harmonics. With superior performance in compensating reactive power, mitigating three-phase imbalance, and suppressing harmonics, it enables rapid, continuous regulation of reactive power.
Product Features:
► Continuous adjustment of reactive power capacity enables stepless compensation.
► It can dynamically and bidirectionally regulate reactive power, compensating both inductive and capacitive loads.
► Each circuit employs modular products, an independent protection system, and a remote monitoring module within the energy management system to track operating parameters.
► Response time ≤ 10 ms; features rapid reactive power compensation and harmonic mitigation, suppressing voltage fluctuations and mitigating reactive power surges from the load.
► It features a four-quadrant reactive power algorithm and is suitable for photovoltaic system compensation.
Technical Specifications:
Application Areas
Indoor, altitude ≤ 2000 mm
Electrical wiring
Three-phase four-wire / three-phase three-wire
System voltage
0.4kV
Voltage deviation
±15%
Frequency
50Hz
Relative humidity
≤90% (40℃)
Ambient temperature
-20℃~+50℃
Control voltage
12V DC
Switching interval
≤10 ms (Thyristor)
Communication method
RS485
Number of parallel units
Parallel expansion: depending on the cabinet size, each cabinet can accommodate up to 8 units.
Filtering range
Filter out characteristic harmonics from the 2nd to the 51st order.
Specification and Model Description:
Transformer Capacity (kVA)
Installed capacity (kvar)
Output capacity (kvar)
Smart Filtering and Compensation Module Configuration
Reactance ratio
Inside the cabinet Circuit breaker
Cabinet dimensions (width × depth × height)
630
267+100A
200+100A
2x33.3+3x66.7+100A
7%
630A
800x800x2200
800
334+150
250+150A
2x33.3+4x66.7+150A
7%
800A
1000x800x2200
1000
400+150A
300+150A
2x33.3+5x66.7+150A
7%
800A
1000x800x2200
1250
440+200A
330+200A
1x40+5x80+2*100A
7%
1000A
1000x800x2200
1600
634+250A
475+250A
1x33.3+9x66.7+150A+100A
7%
800A
2x(1000x800x2200)
2000
800+300A
600+300A
2x33.3+11x66.7+2x150A
7%
1000A
2x(1000x800x2200)
2500
1000+400A
750+400A
2x33.3+14x66.7+4x100A
7%
800A
3x(1000x800x2200)
3150
1280+600A
960+600A
16x80+4x150A
7%
1000A
3x(1000x800x2200)
Product Selection:

Product Dimensions Diagram:
Design Requirements:
- 1. All filter‑compensation modules are equipped with ventilation systems; the front panel of the cabinet must feature a perforated, ventilated design, while the rear panel must be fitted with a fan.
- 2. For single cabinets with a capacity ≤ 400 kvar, the rear door must be equipped with four fans, each providing an exhaust airflow of no less than 40 m³/min.
- 3. For single cabinets with a capacity exceeding 400 kvar, six fans must be installed at the rear door, with an exhaust airflow rate of no less than 60 m³/min.
- 4. When natural air cooling at the installation location of the modular switchgear cabinet is insufficient, an air-conditioning system must be installed in the room.
- 5. The equipment should undergo a power-off maintenance every three months, during which the cabinet door is opened and dust is cleaned out.
Key words:- Tsvggd
- compensation
- system
- capacity
- module
- protection
- voltage
- device
RELATED PRODUCTS
PRODUCT MESSAGE
Follow Us
Guangdong Guangda Electric Co. Ltd.
Tel:18028173868
E-mail:gdgddq@126.com
Web:www.gd96.com
Add :Building 3, No. 613, Xingtan Shuixiang Avenue, Gaozan Village, Xingtan Town, Shunde District, Foshan City, Guangdong Province