High-Voltage Automatic Reactive Power Compensation and Harmonic Elimination Device

The high-voltage automatic reactive power compensation and harmonic elimination device is a new product developed to meet the demands of enhanced comprehensive automation in 6 kV and 10 kV power systems. The device primarily comprises a modular vacuum contactor, capacitors, reactors, a discharge unit, a controller, and a microprocessor-based protective relay. It can adjust the system’s power factor in response to changes in grid conditions, thereby reducing transformer and line losses, increasing transmission capacity, and maximizing the economic efficiency of transmission and distribution equipment, while also suppressing system harmonics and improving power quality.

Hotline:

Product Consultation
  • Summary
  • Product Selection
  • Distinction
  • Parameter
  • Explain
  • Size
    • Commodity name: High-Voltage Automatic Reactive Power Compensation and Harmonic Elimination Device

    The high-voltage automatic reactive power compensation and harmonic elimination device is a new product developed to meet the demands of enhanced comprehensive automation in 6 kV and 10 kV power systems. The device primarily comprises a modular vacuum contactor, capacitors, reactors, a discharge unit, a controller, and a microprocessor-based protective relay. It can adjust the system’s power factor in response to changes in grid conditions, thereby reducing transformer and line losses, increasing transmission capacity, and maximizing the economic efficiency of transmission and distribution equipment, while also suppressing system harmonics and improving power quality.

    The high-voltage automatic reactive power compensation and harmonic elimination device is a new product developed to meet the demands of increasingly sophisticated integrated automation in 6 kV and 10 kV power systems. The device primarily comprises a modular vacuum contactor, capacitors, reactors, a discharge unit, a controller, and a microprocessor-based protective relay. It dynamically adjusts to variations in the grid’s power factor, thereby improving system power factor, reducing losses in transformers and transmission lines, enhancing transmission capacity, and maximizing the economic efficiency of transmission and distribution equipment. At the same time, it suppresses system harmonics and improves power quality.
           

    Product Features:

    Strong harmonic suppression capability, effectively mitigating harmonics of the 5th order and above.

    The secondary control components are centrally installed in a dedicated capacitor room, with safe clearance between high- and low-voltage equipment for convenient maintenance.

    It features multiple operating modes, including automatic control, manual operation, and remote control.

    Independent open-delta voltage protection and overcurrent protection are provided for each capacitor bank.

     

    Technical Specifications:

    Application Areas

    Indoor, altitude ≤ 2000 mm

    System voltage

    6kV/10kV

    Voltage deviation

    ±10%

    Frequency

    50Hz

    Relative humidity

    ≤90% (40℃)

    Ambient temperature

    -20℃~45℃  

    Control voltage

    220V AC/DC

     

    Specification and Model Description:

    Transformer capacity (kW)

    Installed capacity (kvar)

    Output capacity (kvar)

    Device model

    Reactance ratio

    Cabinet dimensions (W×H×D)

    300

    200

    150

    MSCGD-200/10-7

    7%

    1000x1500x2300

    450

    250

    185

    MSCGD-250/10-7

    7%

    1000x1500x2300

    500

    300

    225

    MSCGD-300/10-7

    7%

    1000x1500x2300

    630

    400

    300

    MSCGD-400/10-7

    7%

    1000x1500x2300

    750

    450

    335

    MSCGD-450/10-7

    7%

    1000x1500x2300

    900

    500

    375

    MSCGD-500/10-7

    7%

    1200x1500x2500

    1000

    600

    450

    MSCGD-600/10-7

    7%

    1200x1500x2500

    1300

    750

    560

    MSCGD-750/10-7

    7%

    1200x1500x2500

    1400

    800

    600

    MSCGD-800/10-7

    7%

    1200x1500x2500

    1500

    900

    675

    MSCGD-900/10-7

    7%

    1200x1500x2500

    1800

    1000

    750

    MSCGD-1000/10-7

    7%

    1200x1500x2500

    2000

    1200

    900

    MSCGD-1200/10-7

    7%

    1200x1500x2500

     

    Product Selection:

    img

     

    Product Dimensions Diagram:

    img
    Key words:
    • High voltage
    • device
    • voltage
    • system
    • capacitor

RELATED PRODUCTS

Fast-acting vacuum circuit breaker


During a short-circuit fault: the fast‑acting vacuum circuit breaker rapidly discharges the energy stored in its energy‑storage capacitor, and the electromagnetic repulsive force generated by eddy currents directly drives the breaker to achieve rapid opening. It can detect a short-circuit fault within 2 ms and complete opening within 4 ms after receiving the command, enabling it to interrupt the fault during the initial phase of the short‑circuit current, thereby preventing overreaching tripping of upstream switches. The trip‑current threshold is customizable. In the absence of a fault: the fast‑acting vacuum circuit breaker is fully compatible with conventional medium‑voltage circuit breakers in terms of operating procedures, physical dimensions, and wiring configurations. It can detect a short-circuit fault within 2 ms and complete opening within 4 ms after receiving the command, allowing it to interrupt the fault during the first peak of the short‑circuit current and preventing overreaching tripping of upstream switches. The trip‑current threshold is also configurable.

KOGD output reactor


Output AC reactor: Used for smoothing and filtering, reducing transient voltage dv/dt, extending motor life, lowering motor noise, minimizing eddy current losses, decreasing leakage currents caused by output higher-order harmonics, and protecting the power switching devices inside the inverter.

Power Quality Online Monitoring Device


The PM600 (S/M/Q) online power quality monitoring device is specifically designed for monitoring the power quality of “Class I loads.” The MP600 (S/M/Q) features high accuracy, excellent stability, a compact footprint, and easy installation, with accuracy fully compliant with the IEC 61000‑4‑30 Class A standard.

Four-quadrant reactive power compensation controller for photovoltaic systems


The MCGD‑G can monitor reactive power and voltage fluctuations in the grid in real time. By adjusting the reactive power output of the photovoltaic system, it achieves reactive power compensation, thereby enhancing grid stability and power quality. At the same time, it intelligently regulates the active power output of the photovoltaic system based on solar irradiance conditions and grid demand, enabling maximum power point tracking and optimized energy utilization.

APFGD Active Filter Cabinet


The APFGD/SVGGD device is a novel power electronic apparatus designed to address power quality issues, employing an external current transformer to continuously monitor the load current in the power grid.

Wall-Mounted Active Power Filter Compensation Module


The active filtering compensation module is a modular product specially developed by Guangda Electric for dynamic harmonic mitigation in 0.4 kV power supply systems. Connected in parallel with the grid, it uses an external current transformer to continuously monitor the load current. Leveraging DSP, FPGA, and CPLD chips, along with cutting-edge rapid harmonic mitigation and reactive power extraction technologies, it swiftly analyzes the harmonic and reactive components of the load current. Based on user-defined setpoints, it generates PWM pulses to drive a bidirectional converter composed of three-level IGBT modules, thereby producing compensation currents that meet grid requirements. This enables precise, real-time compensation of harmonic and reactive currents, ultimately enhancing power quality. Active modular power quality products comprise three categories: static var generators (SVG), three-phase unbalance compensators (ASVG), and active filters (APF).

PRODUCT MESSAGE