undefined
+
  • undefined

High-Voltage Dynamic Reactive Power Compensation Device

The GD‑SVG series high‑voltage dynamic reactive power compensation devices are IGBT‑based reactive power compensation systems that can rapidly and continuously deliver either capacitive or inductive reactive power. They enable control at the point of measurement to maintain constant reactive power, constant voltage, and a stable power factor, thereby ensuring the stable, efficient, and high‑quality operation of the power system. The GD‑SVG significantly improves power quality at the connection point between the load and the public grid, for example by increasing the power factor, balancing three‑phase voltages, suppressing voltage flicker and fluctuations, and mitigating harmonic distortion. With their ease of operation, high performance, and exceptional reliability, the SVG product series is specifically designed to meet users’ pressing needs for improving the power factor of transmission and distribution networks, controlling harmonics, and compensating negative‑sequence currents.

Hotline:

Product Consultation
  • Summary
  • Product Selection
  • Distinction
  • Parameter
  • Explain
  • Size
    • Commodity name: High-Voltage Dynamic Reactive Power Compensation Device

    The GD‑SVG series high‑voltage dynamic reactive power compensation devices are IGBT‑based reactive power compensation systems that can rapidly and continuously deliver either capacitive or inductive reactive power. They enable control at the point of measurement to maintain constant reactive power, constant voltage, and a stable power factor, thereby ensuring the stable, efficient, and high‑quality operation of the power system. The GD‑SVG significantly improves power quality at the connection point between the load and the public grid, for example by increasing the power factor, balancing three‑phase voltages, suppressing voltage flicker and fluctuations, and mitigating harmonic distortion. With their ease of operation, high performance, and exceptional reliability, the SVG product series is specifically designed to meet users’ pressing needs for improving the power factor of transmission and distribution networks, controlling harmonics, and compensating negative‑sequence currents.

    The GD‑SVG series high‑voltage dynamic reactive power compensation devices are IGBT‑based reactive power compensation systems that can rapidly and continuously deliver either capacitive or inductive reactive power. They enable control at the point of measurement to maintain constant reactive power, constant voltage, and a stable power factor, thereby ensuring the stable, efficient, and high‑quality operation of the power system. The GD‑SVG significantly improves power quality at the connection point between the load and the public grid, including enhancing the power factor, balancing three‑phase voltages, suppressing voltage flicker and fluctuations, and mitigating harmonic distortion.

    The SVG series products, which are easy to operate, high‑performance, and highly reliable, have been specifically designed to meet users’ pressing needs for improving the power factor of transmission and distribution networks, mitigating harmonics, and compensating negative-sequence currents.

     

    Product Features:

    It tracks load variations in real time, dynamically and continuously provides smooth reactive power compensation to improve the system power factor, mitigates harmonics on a real-time basis, compensates negative-sequence currents, and enhances grid power quality.

    It features comprehensive protection functions, including overvoltage, overcurrent, module overheating, and unequal‑voltage protection, and can capture fault waveforms in real time.

    The power units are mounted using power connectors, facilitating on-site installation, inspection, and maintenance, thereby effectively enhancing efficiency.

    The power circuit features a modular design, ensuring easy maintenance and excellent interchangeability.

     

    Technical Specifications:

    Rated capacity

    ±1 Mvar ~ ±100 Mvar

    Application Areas

    Indoor only, altitude ≤2000mm

    System voltage

    6kV/10kV

    Frequency

    50Hz

    Active power loss

    ≤0.8%

    Total Harmonic Current Distortion (THDi)

    ≤3%

    Starting power

    5kvar

    Response time

    ≤5ms

    Parallel connection method

    Supports parallel operation in multi-unit networking, enables comprehensive compensation across multiple busbars, and accommodates up to four sets of FC‑based comprehensive compensation control.

    Protection rating

    Indoor models meet IP20, while outdoor models meet IP44.

    Ambient temperature

    -20℃~45℃

    Control voltage

    AC: 380V, 220V, or DC: 220V

    Communication protocol

    Supports MODBUS_RTU and ProfiBUS.

     

    Specification and Model Description:

    Product model

    Voltage Level (kV)

    Rated Capacity (Mvar)

    External dimensions

    Note

    Weight (kg)

    Overall width (mm)

    Height (mm)

    Depth (mm)

    GD-SVG-C1.0/6

    6kV

    1.0

    3300

    2400

    1400

    Core Reactance

    2290

    GD-SVG-C1.5/6

    1.5

    2600

    GD-SVG-C2.0/6

    2.0

    2850

    GD-SVG-C3.0/6

    3.0

    3400

    3060

    GD-SVG-C4.0/6

    4.0

    3800

    3750

    GD-SVG-C5.0/6

    5.0

    4260

    GD-SVG-C6.0/6

    6.0

    3600

    Air-core reactor

    2750

    GD-SVG-C7.0/6

    7.0

    3450

    GD-SVG-C8.0/6

    8.0

    5600

    4600

    GD-SVG-C9.0/6

    9.0

    4700

    GD-SVG-C10.0/6

    10.0

    4800

    GD-SVG-C11.0/6

    11.0

    4900

    GD-SVG-C12.0/6

    12.0

    5000

     

    Product Selection:

    img

     

    Product Dimensions Diagram: 
    img

    Key words:
    • High voltage
    • voltage
    • reactance
    • capacitance

RELATED PRODUCTS

Fast-acting vacuum circuit breaker


During a short-circuit fault: the fast‑acting vacuum circuit breaker rapidly discharges the energy stored in its energy‑storage capacitor, and the electromagnetic repulsive force generated by eddy currents directly drives the breaker to achieve rapid opening. It can detect a short-circuit fault within 2 ms and complete opening within 4 ms after receiving the command, enabling it to interrupt the fault during the initial phase of the short‑circuit current, thereby preventing overreaching tripping of upstream switches. The trip‑current threshold is customizable. In the absence of a fault: the fast‑acting vacuum circuit breaker is fully compatible with conventional medium‑voltage circuit breakers in terms of operating procedures, physical dimensions, and wiring configurations. It can detect a short-circuit fault within 2 ms and complete opening within 4 ms after receiving the command, allowing it to interrupt the fault during the first peak of the short‑circuit current and preventing overreaching tripping of upstream switches. The trip‑current threshold is also configurable.

KOGD output reactor


Output AC reactor: Used for smoothing and filtering, reducing transient voltage dv/dt, extending motor life, lowering motor noise, minimizing eddy current losses, decreasing leakage currents caused by output higher-order harmonics, and protecting the power switching devices inside the inverter.

Power Quality Online Monitoring Device


The PM600 (S/M/Q) online power quality monitoring device is specifically designed for monitoring the power quality of “Class I loads.” The MP600 (S/M/Q) features high accuracy, excellent stability, a compact footprint, and easy installation, with accuracy fully compliant with the IEC 61000‑4‑30 Class A standard.

Four-quadrant reactive power compensation controller for photovoltaic systems


The MCGD‑G can monitor reactive power and voltage fluctuations in the grid in real time. By adjusting the reactive power output of the photovoltaic system, it achieves reactive power compensation, thereby enhancing grid stability and power quality. At the same time, it intelligently regulates the active power output of the photovoltaic system based on solar irradiance conditions and grid demand, enabling maximum power point tracking and optimized energy utilization.

APFGD Active Filter Cabinet


The APFGD/SVGGD device is a novel power electronic apparatus designed to address power quality issues, employing an external current transformer to continuously monitor the load current in the power grid.

Wall-Mounted Active Power Filter Compensation Module


The active filtering compensation module is a modular product specially developed by Guangda Electric for dynamic harmonic mitigation in 0.4 kV power supply systems. Connected in parallel with the grid, it uses an external current transformer to continuously monitor the load current. Leveraging DSP, FPGA, and CPLD chips, along with cutting-edge rapid harmonic mitigation and reactive power extraction technologies, it swiftly analyzes the harmonic and reactive components of the load current. Based on user-defined setpoints, it generates PWM pulses to drive a bidirectional converter composed of three-level IGBT modules, thereby producing compensation currents that meet grid requirements. This enables precise, real-time compensation of harmonic and reactive currents, ultimately enhancing power quality. Active modular power quality products comprise three categories: static var generators (SVG), three-phase unbalance compensators (ASVG), and active filters (APF).

PRODUCT MESSAGE