Incoming / Outgoing reactor

Inverter special incoming line reactor, connected in series between inverter incoming line end and power supply, inhibit surge voltage and surge current, protect inverter; Improve the power factor of frequency converter and suppress harmonic current; Filter harmonic voltage and harmonic current to improve the quality of power grid. Series inverter dedicated line (output) reactor, in between the client and load frequency converter, reduce the power frequency transient overvoltage, improvement of the voltage distribution on long transmission line, ease to the inverter output three-phase imbalance, reduce energy loss on the line, to prevent possible since the excitation generator with long line resonance phenomenon.

Hotline:

Product Consultation
  • Summary
  • Product Selection
  • Distinction
  • Parameter
  • Explain
  • Size
    • Commodity name: Incoming / Outgoing reactor

    Inverter special incoming line reactor, connected in series between inverter incoming line end and power supply, inhibit surge voltage and surge current, protect inverter; Improve the power factor of frequency converter and suppress harmonic current; Filter harmonic voltage and harmonic current to improve the quality of power grid. Series inverter dedicated line (output) reactor, in between the client and load frequency converter, reduce the power frequency transient overvoltage, improvement of the voltage distribution on long transmission line, ease to the inverter output three-phase imbalance, reduce energy loss on the line, to prevent possible since the excitation generator with long line resonance phenomenon.

    Inverter special incoming line reactor, connected in series between inverter incoming line end and power supply, inhibit surge voltage and surge current, protect inverter; Improve the power factor of frequency converter and suppress harmonic current; Filter harmonic voltage and harmonic current to improve the quality of power grid.

    Series inverter dedicated line (output) reactor, in between the client and load frequency converter, reduce the power frequency transient overvoltage, improvement of the voltage distribution on long transmission line, ease to the inverter output three-phase imbalance, reduce energy loss on the line, to prevent possible since the excitation generator with long line resonance phenomenon.

    Key words:
    • incoming
    • the
    • line
    • and
    • inverter
    • power
    • frequency
    • current
    • of
    • harmonic
  • img

  • ►High performance H grade insulation material is used.

    ►Strong short-circuit resistance, short time overload ability.

    ►The design has low flux density, good linearity and strong overload capacity.

    ►Adopt high quality and low loss cold rolled oriented silicon steel sheet

    ►Low loss, low temperature rise, low noise, low operating cost.

  • Location

    Indoor only,altitude ≤1000mm

    Insulation

    0.23kV~0.69kV,AC3500V/60s

    Frequency

    50Hz/60Hz

    Temperture

    The maximum temperatur is 45℃, The average temperatur within  24 hours shall not be higher than  35℃.

    Temperature rise

    Rated current operating coil temperature rise shall not exceed 40℃ (resistance method)

    Noise

    Rated current operating noise ≤60dB

  • 380V Incoming  Reactor

    Model

    Converter power
    (kW)

    Size(W*H*D)

    Install(E*F)

    Model

    Converter power
    (kW)

    Size(W*H*D)

    Install(E*F)

    KIGD-10A-H3-0.4

    ≤4

    240*140*140

    200*75

    KIGD-200A-H3-0.4

    75

    240*190*350

    200*105

    KIGD-15A-H3-0.4

    5.5

    240*140*140

    200*75

    KIGD-250A-H3-0.4

    90

    240*200*350

    200*125

    KIGD-29A-H3-0.4

    11

    240*140*180

    200*75

    KIGD-290A-H3-0.4

    110

    240*200*390

    200*125

    KIGD-40A-H3-0.4

    15

    240*140*200

    200*75

    KIGD-300A-H3-0.4

    132

    240*190*420

    200*115

    KIGD-50A-H3-0.4

    18.5

    240*140*220

    200*75

    KIGD-400A-H3-0.4

    160

    240*230*420

    200*145

    KIGD-60A-H3-0.4

    22

    240*140*220

    200*75

    KIGD-475A-H3-0.4

    185

    240*255*450

    200*185

    KIGD-80A-H3-0.4

    30

    240*140*220

    200*75

    KIGD-520A-H3-0.4

    200

    240*270*430

    200*195

    KIGD-110A-H3-0.4

    37

    240*180*240

    200*95

    KIGD-600A-H3-0.4

    250

    240*270*430

    200*195

    KIGD-125A-H3-0.4

    45

    240*190*220

    200*105

    KIGD-660A-H3-0.4

    280

    240*270*430

    200*195

    KIGD-150A-H3-0.4

    55

    240*190*260

    200*105

     

     

     

     

    380V Outgoing Reactor

    Model

    Converter power
    (kW)

    Size(W*H*D)

    Install(E*F)

    Model

    Converter power
    (kW)

    Size(W*H*D)

    Install(E*F)

    KOGD-10A-H3-0.4

    ≤4

    240*135*140

    200*75

    KOGD-200A-H3-0.4

    75

    240*170*350

    200*95

    KOGD-15A-H3-0.4

    5.5

    240*135*140

    200*75

    KOGD-250A-H3-0.4

    90

    240*200*350

    200*125

    KOGD-29A-H3-0.4

    11

    240*140*155

    200*75

    KOGD-290A-H3-0.4

    110

    240*200*390

    200*125

    KOGD-40A-H3-0.4

    15

    240*140*165

    200*75

    KOGD-300A-H3-0.4

    132

    240*200*390

    200*125

    KOGD-50A-H3-0.4

    18.5

    240*135*190

    200*75

    KOGD-400A-H3-0.4

    160

    240*210*420

    200*145

    KOGD-60A-H3-0.4

    22

    240*140*170

    200*75

    KOGD-475A-H3-0.4

    185

    240*220*450

    200*185

    KOGD-80A-H3-0.4

    30

    240*150*175

    200*75

    KOGD-520A-H3-0.4

    200

    240*255*430

    200*185

    KOGD-110A-H3-0.4

    37

    240*180*190

    200*95

    KOGD-600A-H3-0.4

    250

    240*260*430

    200*185

    KOGD-125A-H3-0.4

    45

    240*180*190

    200*95

    KOGD-660A-H3-0.4

    280

    240*260*430

    200*185

    KOGD-150A-H3-0.4

    55

    240*180*230

    200*95

     

  • img

RELATED PRODUCTS

Temperature on-line monitoring device


WTGD-801 is a set of advanced and practical switch cabinet electric contact online temperature monitoring device, through the wireless temperature measurement module to the online temperature control points for real-time monitoring, and the wireless receiving module will be transmitted to the device through RS485 bus related data, through the LCD screen display the real-time temperature of each monitoring point, It has overtemperature alarm function, system platform function and data communication function.

Insulation on-line monitoring device


JYGD-01 insulation online monitoring device can on-line monitoring the insulation states of high and low voltage equipment, the use of the device for diagnostic line cables, insulators, surge arrester, vacuum switch devices such as the shortcomings and hidden danger of accidents in the early, control of sudden accidents, insulation monitoring of electrical equipment insulation performance of the stand or fall provides effective information, and directly influences the safe and reliable operation of the equipment.

Intelligent electricity monitoring terminal


GD-320 intelligent electricity monitoring terminal has the functions of high-precision three-phase voltage, current and power measurement, time-sharing billing, demand calculation, harmonic calculation, fixed-value off-limit, data freezing, residual current protection and temperature protection.

Device level filter


Device level filter is designed for power electronic equipment to reduce harmonic matching products, it can make the three-phase rectifier circuit generated harmonic current to meet any harmonic standard requirements, improve the anti-surge interference ability of equipment. It is the ideal supporting equipment for inverter, UPS, all kinds of power supply, intermediate frequency furnace and other power electronic equipment. Its products have long service life, small loss, currently belongs to the domestic industry leader.

Incoming / Outgoing reactor


Inverter special incoming line reactor, connected in series between inverter incoming line end and power supply, inhibit surge voltage and surge current, protect inverter; Improve the power factor of frequency converter and suppress harmonic current; Filter harmonic voltage and harmonic current to improve the quality of power grid. Series inverter dedicated line (output) reactor, in between the client and load frequency converter, reduce the power frequency transient overvoltage, improvement of the voltage distribution on long transmission line, ease to the inverter output three-phase imbalance, reduce energy loss on the line, to prevent possible since the excitation generator with long line resonance phenomenon.

Sinusoidal filter


Sinusoidal filter is mainly used to solve the harmonic problem at the output of the inverter. The sinusoidal filter can convert the PWM wave output of the inverter into sinusoidal wave, reduce the voltage impact of the PWM pulse output of the inverter, reduce the traveling wave reflection phenomenon at the motor end, and prevent the insulation breakdown of the motor, resulting in cable burst. The function of long-distance transmission of frequency converter is realized.