PROJECT CASE

Guangda Electric Is A Professional Organization Dedicated To Solving Power Quality Problems Of Users

The equipment-level filter for air compressors and motors with frequency converters can improve the power factor to 1.00.


User: Gansu Jinchang Chemical Industry Group Co., Ltd. Name: Equipment-level Filter Model: SSFGD-220/0.4 Load: Air compressor, motor with frequency converter 1. Power Factor: Improved the system's power factor from 0.86 to 1.00; 2. Filtering Effect: Total harmonic current distortion rate decreased from 57.2% to 5.9%; 3. Temperature Noise: Sharp noise disappeared, ΔT reduced by 5K, allowing full utilization of transformer capacity; 4. Other Equipment Issues: After filtering, the instrument displays correctly, no abnormalities in industrial control, and no false protection.


2025-02-13

The charging pile filter optimizes the charging effect of the charging pile, reducing the total harmonic current distortion rate to 4.6%.


User: Shenzhen Waterma Battery Co., Ltd. Name: Equipment-level Filter Model: SSFGD-220/0.4 Load: 380V AC Charging Pile 1. Filtering Effect: Total harmonic current distortion rate decreased from 29% to 4.6%; 2. Impact on Charging Pile: Reduces measurement error of the charging pile.


2025-02-13

How to manage harmonic current pollution from UPS in textile factories?


Harmonic Control Typical Case in the Textile Industry (Guangdong Minxing Wool Knitting Co., Ltd.) Project Background: A certain textile factory's main loads are high-capacity UPS and computer knitting machines. The UPS provides high-quality power with high voltage regulation accuracy and low waveform distortion. However, since the UPS is a nonlinear load, the rectifier in the UPS generates a large amount of harmonic current, resulting in a high current distortion rate on the grid side. This not only causes harmonic pollution to the power grid but also affects the normal operation of the reactive power compensation cabinet, necessitating harmonic control. Control Plan: Based on on-site test results, it was found that the reason the reactive power compensation cabinet could not be normally engaged was due to the harmonic current generated by the UPS.


2025-02-13

How are current harmonics managed in the variable frequency drives of water treatment plants?


Typical Case of Harmonic Control in Water Treatment Plant (Nanjing Pukou Water Treatment Plant)\nProject Background: A certain water treatment plant operates its intake pump motor using a high-power variable frequency drive. Due to the high-power diode rectification and high-power thyristor inversion within the variable frequency drive, high-order current harmonics are generated in the input and output circuits, which interfere with the power supply system, loads, and other nearby electrical equipment, affecting the normal operation of metering instruments.\nControl Plan: After on-site testing and analysis, it was determined that using one of our 100A active power filters could effectively suppress the harmonics, allowing the metering instruments to function normally.\nControl Effect: After the control measures were implemented, the harmonics were effectively suppressed.


2025-02-13

How can pharmaceutical companies prevent frequency converters in fermentation workshops from interfering with the power grid?


The main harmonic source under the 10kV main transformer of a certain pharmaceutical factory is the fermentation workshop. This workshop has 4 transformers (2000kVA, 10/0.4kV), with every two connected in parallel as a group, divided into two groups for independent operation. One group (on the east side) is connected to 6 variable frequency drives (VFDs) with motor capacities of 280KW each, while the other group (on the west side) is connected to 7 VFDs with motor capacities of 200KW each. The VFDs generate significant non-sinusoidal distorted currents during operation, causing serious interference to the power grid. To purify the power grid, improve the system power factor, and eliminate harmonics.


2025-02-13

Harmonic Control Solutions for Tobacco Leaf Processing Plants with Variable Frequency Drives


The tobacco leaf processing company has harmonic sources mainly from two distribution rooms. The load is the "leaf stripping line," which filters out impurities from the tobacco leaves to obtain impurity-free tobacco leaves. This process is achieved through inverters and motors. The inverter is a significant source of harmonics, which causes serious harmonic pollution and interference in the system, necessitating harmonic treatment. Treatment plan: Based on the analysis of the test data, we recommend using 7 active power filters in the two distribution rooms: two units in the first distribution room and the remaining units in the second distribution room.


2025-02-13